Heat Pump Defrost Timer for Intercity Products; Lennox equipment.
Technical Specifications for Input:
Voltage: 18 to 30 Vac;
Frequency: 50/60Hz;
Power Consumption: 1 watt maximum.
Technical Specifications for Output:
Compressor Contacts;
Type: Triac;
Rating: 1 Amp.
Technical Specifications for Defrost Relay:
Type: Triac;
Rating: 1 Amp.
Technical Specifications for Time Delays:
Anti-Short Cycle Delay: 3 minutes;
Defrost Time: Fixed 10 minutes + 5%;
Interval Time Between Defrosts: Pin-selectable 30/60/90 minutes;
Test Time: Short across test terminals reduces test time 256x;
Power on Reset Time: 500ms.
Replaces Part Numbers: ICM307; ICM-307C; ICM307C; 1093410; 86G16; DT2.
Used in Lennox Models: CHP16-6535Y; HP22-411-1P;
HP25-311-1P; HP19; HP22; HP24; HP23; 10HP; HP25; HP26 series.