MultipleCNT2184Integrated 2-Stage HSI Control308.00

Integrated 2-Stage Hot Surface Igniton (HSI) Control for American Standard; Trane equipment. For applications using Two Speed Inducer, Two Stage Gas Valve and Three Stage Circulation Blower Motor. Techncial Specifications: For use with all gases. Input: 25 VAC, 60 Hz. Ignition Output: 6.0 @ 120 VAC. MV Output: 1.5 AMPs @ 25 VAC. Inducer Output: 1.5 FLA, 3.0 LRA @ 120 VAC. Electronic Air Cleaner and Humidifer Output: 1.0 AMPs @ 120 VAC. Circulation Blower Output: 14.5 FLA, 25.0 CRA @ 120 VAC. Trial for Igniton: 6 seconds: Prepurge: 0 seconds. Retries: 2 attempts, 3 Post Purge: 5 seconds. Circulation Blower Heat on Delay: 45 seconds. Replaces Part Numbers: CNT2184; CNT1308; 50A51-405; 50A51405; 50A51-495; 50A51495; 50A51-495S1; 50A51495S1. Used in American Standard Models: ADD080R936B0; ADD100R945C; AUD060R936A1; AUD060R936A2; AUD060R936A3; AUD080R9BCH6; AUD080R948H3; AUD080R948H4; AUD100R948A0; AUD100R948H4; AUD100R954K; AUD100R960A1. Used in Comfortmaker; Heil; Intercity Products (ICP); Snyder General; Tempstar Models: NUGV075AH01; NUGV075AH02; NUGV075AH03; NUGV100AH01; NUGV100AH02; NUGV100AH03. Used in Trane Models: TDD080R936B0; TDD100R945C; TUD060R936A1; TUD060R936A2; TUD060R936A3; TUD080R9BCH6; TUD080R948H3; TUD080R948H4; TUD100R948A0; TUD100R948H4; TUD100R954K; TUD100R960A1.

Specifications

ParamterValue
Package Quantity1
TypeIntegrated Hot Surface Ignition